version 1.1
1
SmartBus P900
-
V16
N
NN
N
USER MANUAL
The BLUGUARD Control Panel is designed for simple operation yet provides the maximum
protection for you. Please read this manual carefully and follow the instructions contained in this
book. Fill in the system information page and store this manual in a safe place for future reference.
Your security system consists of a main control panel, one or more keypads and home automation
(HA) modules, various sensors and detectors. An enclosure will contain the control panel, which
includes the system electronics and standby battery.
To ensure that your system is functioning, it is important that you test your system weekly. Please
refer to testing procedures section in this manual. If your system does not function properly, please
contact your system installer for services. There is normally no reason for anyone other than the
installer or service professional to have access to the control panel.
Even though BLUGUARD is an advanced security system, it does not 100% guarantee the
protection against burglary, fire or other loses. Any alarm system whether commercial or residential
is subjected to compromise or failure-to-warn for a variety of reasons. These include:
Intruders may gain access through unprotected openings or have the technical
sophistication to bypass an alarm sensor or disconnect an alarm warning device.
Intrusion detectors, smoke detectors and many sensing devices will not operate without
power. Devices powered by AC will not work if there is no AC power supply for any reason
and the back-up battery is missing, dead or improperly installed.
Alarm warning devices such as sirens may not alert people or wake up sleepers if they are
located on the other side of closed or partly closed doors.
Telephone line needed to transmit alarm events from the premise to a central monitoring
station may be out or temporary out of service. Telephone line is subject to compromise by
sophisticated method of attack.
Smoke detector used in conjunction with the alarm system may not sense fire that start
from where smoke cannot reach the detector such as wall, roof or the other side of the
doors. Smoke detector also may not sense a fire on another level of the residence or
building. In general, detectors may not always warn you about fire caused by carelessness
and safety hazards like smoking, violent explosions, escaping gas, improper storage of
flammable material, overloaded electrical circuits, children playing with matches.
The most common cause of an alarm system not functioning properly when an intrusion or
fire occurs is inadequate maintenance. Therefore, your system should be tested weekly to
ensure all detectors or sensors are working properly.
Installing an alarm system may make you eligible for lower insurance rates but an alarm
system is not a substitute for insurance. Homeowners, property owners and renters should
continue to insure their lives and properties.
SYSTEM INFORMATION
Central Monitoring Station Number :
________________________________
Central Monitoring Station Account Number :
________________________________
Note: All information is subject to changes without prior notice
.
TESTING
LIMITATIONS
Vista de página 0
1 2 3 4 5 6 ... 30 31

Resumo do Conteúdo

Página 1

version 1.1 1SmartBus P900-V16NNNN USER MANUAL The BLUGUARD Control Panel is designed for simple operation yet provides the maximum

Página 2

version 1.1 10SmartBus P900-V16NNNN USER MANUAL [∗∗∗∗] + [USER CODE] + [#] (Leave via ENTRY/EXIT Zone) 1. Ensure that all zone indicators are

Página 3

version 1.1 11SmartBus P900-V16NNNN USER MANUAL [3] (Press and hold down for 2 seconds) 1. This arming mode is ideal for NIGHT time arming

Página 4

version 1.1 12SmartBus P900-V16NNNN USER MANUAL 5. The P1 indicator will illuminate and the keypad audible indicator will sound on and off for the

Página 5

version 1.1 13SmartBus P900-V16NNNN USER MANUAL b. Keypad Disarming c. Remote Control Disarming d. Timer Auto Disarming e. Telephone Remote Di

Página 6

version 1.1 14SmartBus P900-V16NNNN USER MANUAL 2. Please refer to User Programming section – Program Auto Disarm Timer. 1. Your system can be

Página 7

version 1.1 15SmartBus P900-V16NNNN USER MANUAL 8. To bypass all zones at once, enter [0] key followed buy [#]. 9. Keypad audible indicator will

Página 8

version 1.1 16SmartBus P900-V16NNNN USER MANUAL ZONE 6 indicator Telephone Line/GSM Personal Reporting Fail ZONE 7 indicator Telephone Line Connect

Página 9

version 1.1 17SmartBus P900-V16NNNN USER MANUAL 1. This key will activate the FIRE ALARM condition when it is held down for 2 seconds. 2. The FI

Página 10 - (Leave via ENTRY/EXIT Zone)

version 1.1 18SmartBus P900-V16NNNN USER MANUAL Zones can be divided into two systems. Based on your requirements, the installer designates which

Página 11

version 1.1 19SmartBus P900-V16NNNN USER MANUAL 3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the co

Página 12

version 1.1 2SmartBus P900-V16NNNN USER MANUAL Alarm Memory This is the history of the most recent violations that occurred the last

Página 13

version 1.1 20SmartBus P900-V16NNNN USER MANUAL 1. This arming mode is ideal for DAY time arming with user still remains in the pro

Página 14

version 1.1 21SmartBus P900-V16NNNN USER MANUAL [0] + [1 or 2] + [#]

Página 15

version 1.1 22SmartBus P900-V16NNNN USER MANUAL 12. If programmed to do so, the keypad will be locked and non-responsive for a prepro

Página 16

version 1.1 23SmartBus P900-V16NNNN USER MANUAL [MODE] + [#] 1. Once all setting is programmed, press [MODE] followed by [#] key to exit. 2.

Página 17

version 1.1 24SmartBus P900-V16NNNN USER MANUAL 6. To exit user programming mode, press [MODE] followed by [#] key. [COMMAND ADDRESS] + [0000]

Página 18

version 1.1 25SmartBus P900-V16NNNN USER MANUAL 2. Enter [19] for auto disarm timer setting. 3. Enter the [AUTO DISARM TIMER] in 24-hour format,

Página 19

version 1.1 26SmartBus P900-V16NNNN USER MANUAL 2. Enter [21] for auto disarm timer setting. 3. Enter the [#] key to erase previous AUTO DISARM T

Página 20

version 1.1 27SmartBus P900-V16NNNN USER MANUAL 3. Enter the [AUTO ON TIMER 2] in 24-hour format, e.g. 8:00pm is 20:00. 4. Enter [#] key to confi

Página 21

version 1.1 28SmartBus P900-V16NNNN USER MANUAL 8. If the system fails to contact the preprogrammed personal telephone number 1, system will conta

Página 22

version 1.1 29SmartBus P900-V16NNNN USER MANUAL Users are advised to test the system as frequent as possible. System must be tes

Página 23

version 1.1 3SmartBus P900-V16NNNN USER MANUAL UNDERSTAND YOUR KEYPAD INDICATORS ZONE

Página 24

version 1.1 30SmartBus P900-V16NNNN USER MANUAL 1. Strobe Light Test allows on-site testing of strobe light functionality. 2. Strobe light will

Página 25

version 1.1 31SmartBus P900-V16NNNN USER MANUAL Telephone Number 2 : _____________________________________________ Dialing Attempt : __

Página 26

version 1.1 4SmartBus P900-V16NNNN USER MANUAL Intelligent Disarm [4-digit User Code] + [#] Intelligent Arming [4-digit User Code] + [#] Away A

Página 27

version 1.1 5SmartBus P900-V16NNNN USER MANUAL PARTITION SYSTEM ENABLED Intelligent Disarm [4-digit User Code] + [#] + [Partition 1] or [Partit

Página 28

version 1.1 6SmartBus P900-V16NNNN USER MANUAL Remark: The system will automatically cut off

Página 29

version 1.1 7SmartBus P900-V16NNNN USER MANUAL USER PROGRAMMING SUMMARY DIAGRAM ENTER

Página 30

version 1.1 8SmartBus P900-V16NNNN USER MANUAL Enter User Programming Mode [ Ж ] + [MODE] + [4-digit Master Code] + [#] Exit User Programming M

Página 31

version 1.1 9SmartBus P900-V16NNNN USER MANUAL Program System Timer System Clock [17] + [Current Time in 24-hour Format] + [#] Program Security